Difference between revisions of "Nortel 4548GT switches"
(16 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
− | = | + | = Luilak/Bulldozer subcluster switches (Nortel 4548GT) = |
The 4500 series Nortel switches are different from all others. A few hints: | The 4500 series Nortel switches are different from all others. A few hints: | ||
* The serial port setting is 9600 8N1 with NO flow control | * The serial port setting is 9600 8N1 with NO flow control | ||
− | * Before the serial port will work, the dip switch on the back of the unit | + | * Before the serial port will work, the dip switch on the back of the unit may need to be set to "BASE". If it is set to "Unit select" you may not get any reasonable response out of the serial port |
− | * | + | * <b>If nothing seems to happen, press <tt>^Y</tt></b> |
+ | * The local user names (for the web interface) are "RO" and "RW", respectively. | ||
== Vendor documentation == | == Vendor documentation == | ||
Line 19: | Line 20: | ||
enable Turn on privileged commands | enable Turn on privileged commands | ||
exit Exit from the EXEC | exit Exit from the EXEC | ||
− | + | ... | |
− | |||
− | |||
− | |||
− | |||
− | |||
== Proposed Configuration == | == Proposed Configuration == | ||
− | Configure trunk using LACP | + | Configure trunk using LACP on ports 47 and 48 (the two right-most ports) and run both VLAN 9 and VLAN 4 tagged over this trunk. All other ports 1-44 are be be untagged ports in VLAN 9. Except on sw-03, which is a 24 port switch! |
+ | |||
+ | Preliminary configuration | ||
+ | |||
+ | ena | ||
+ | conf t | ||
+ | autosave enable | ||
+ | cli password switch serial local | ||
+ | cli password switch telnet local | ||
+ | cli password switch read-only "IPMILOW" | ||
+ | cli password switch read-write "IPMI" | ||
+ | cli password stack read-only "IPMILOW" | ||
+ | cli password stack read-write "IPMI" | ||
+ | snmp-server community "public" ro | ||
+ | snmp-server community "COMPLEXHASH" rw | ||
+ | snmp-server contact "grid.sysadmin@nikhef.nl" | ||
+ | snmp-server name "farmnet-sw-valentine-<i>XX</i>" | ||
+ | snmp-server location "H139" | ||
+ | |||
+ | Disable spanning tree for safety | ||
+ | |||
+ | interface FastEthernet ALL | ||
+ | spanning-tree port 1-48 learning fast | ||
+ | spanning-tree port 1-48 cost 1 priority 80 | ||
+ | exit | ||
+ | |||
+ | Create the appropriate vlans | ||
+ | |||
+ | vlan create 4 name IPMI type port | ||
+ | vlan create 9 name FARMNET type port | ||
+ | vlan configcontrol automatic | ||
+ | vlan members remove 1 1-48 | ||
+ | vlan ports 1-46 tagging disable | ||
+ | vlan ports 47-48 tagging enable | ||
+ | vlan ports 47-48 tagging tagAll | ||
+ | vlan members 9 1-46 | ||
+ | vlan members add 4 47-48 | ||
+ | vlan members add 9 47-48 | ||
+ | |||
+ | Configure the proper type of trunking: | ||
+ | |||
+ | no mlt 1 | ||
+ | int FastEthernet 47-48 | ||
+ | lacp aggregation port 47-48 enable | ||
+ | lacp mode port 47-48 active | ||
+ | exit | ||
+ | |||
+ | The management interface of the switch can be assigned to VLAN4 now and then configured with the ip address of the switch using: | ||
vlan mgmt 4 | vlan mgmt 4 | ||
− | ip address 172.20. | + | ip address 172.20.1.YYY |
ip address netmask 255.255.0.0 | ip address netmask 255.255.0.0 | ||
ip default-gateway 172.20.255.254 | ip default-gateway 172.20.255.254 | ||
+ | |||
+ | where | ||
+ | {|style="background:silver; color:black" | ||
+ | | farmnet-sw-valentine-01.ipmi.nikhef.nl || 172.20.1.248 | ||
+ | |- | ||
+ | | farmnet-sw-valentine-02.ipmi.nikhef.nl || 172.20.1.249 | ||
+ | |- | ||
+ | | farmnet-sw-valentine-03.ipmi.nikhef.nl || 172.20.1.250 | ||
+ | |- | ||
+ | | farmnet-sw-valentine-01S.ipmi.nikhef.nl || 172.20.1.245 | ||
+ | |- | ||
+ | | farmnet-sw-valentine-02S.ipmi.nikhef.nl || 172.20.1.246 | ||
+ | |- | ||
+ | | farmnet-sw-valentine-03S.ipmi.nikhef.nl || 172.20.1.247 | ||
+ | |} | ||
+ | |||
+ | Try and save the configuration: | ||
+ | |||
+ | exit | ||
+ | copy config nvram | ||
+ | |||
+ | and check the LACP status with | ||
+ | |||
+ | sho lacp debug member 47-48 | ||
+ | |||
+ | == Deel configuration == | ||
+ | |||
+ | The link aggregation group on deel should also be LACP (802.3ad, i.e., dynamic) | ||
+ | |||
+ | lag "farmnet-sw-valentine-01" dynamic | ||
+ | ports e 13/3 to 13/4 | ||
+ | primary-port 13/3 | ||
+ | deploy | ||
+ | port-name "farmnet-sw-valentine-01-A" ethernet 13/3 | ||
+ | port-name "farmnet-sw-valentine-01-A" ethernet 13/4 | ||
+ | exit | ||
+ | |||
+ | lag "farmnet-sw-valentine-02" dynamic | ||
+ | ports e 13/5 to 13/6 | ||
+ | primary-port 13/5 | ||
+ | deploy | ||
+ | port-name "farmnet-sw-valentine-02-A" ethernet 13/5 | ||
+ | port-name "farmnet-sw-valentine-02-A" ethernet 13/6 | ||
+ | exit | ||
+ | |||
+ | lag "farmnet-sw-valentine-03" dynamic | ||
+ | ports e 13/11 to 13/12 | ||
+ | primary-port 13/11 | ||
+ | deploy | ||
+ | port-name "farmnet-sw-valentine-03-A" ethernet 13/11 | ||
+ | port-name "farmnet-sw-valentine-03-A" ethernet 13/12 | ||
+ | exit | ||
+ | |||
+ | and update the cricket configuration ... |
Latest revision as of 15:55, 3 September 2009
Luilak/Bulldozer subcluster switches (Nortel 4548GT)
The 4500 series Nortel switches are different from all others. A few hints:
- The serial port setting is 9600 8N1 with NO flow control
- Before the serial port will work, the dip switch on the back of the unit may need to be set to "BASE". If it is set to "Unit select" you may not get any reasonable response out of the serial port
- If nothing seems to happen, press ^Y
- The local user names (for the web interface) are "RO" and "RW", respectively.
Vendor documentation
- The documentation for the 4547GT Nortel switches is at http://support.nortel.com/go/main.jsp?cscat=DOCUMENTATION&poid=18122
- Product page http://products.nortel.com/go/product_content.jsp?prod_id=60960
- Picture of 4548GT at http://www.nortel.com/products/01/passport/4500/images/ers_4548gt_1000x284.jpg
What You Should See
4548GT> Exec commands: enable Turn on privileged commands exit Exit from the EXEC ...
Proposed Configuration
Configure trunk using LACP on ports 47 and 48 (the two right-most ports) and run both VLAN 9 and VLAN 4 tagged over this trunk. All other ports 1-44 are be be untagged ports in VLAN 9. Except on sw-03, which is a 24 port switch!
Preliminary configuration
ena conf t autosave enable cli password switch serial local cli password switch telnet local cli password switch read-only "IPMILOW" cli password switch read-write "IPMI" cli password stack read-only "IPMILOW" cli password stack read-write "IPMI" snmp-server community "public" ro snmp-server community "COMPLEXHASH" rw snmp-server contact "grid.sysadmin@nikhef.nl" snmp-server name "farmnet-sw-valentine-XX" snmp-server location "H139"
Disable spanning tree for safety
interface FastEthernet ALL spanning-tree port 1-48 learning fast spanning-tree port 1-48 cost 1 priority 80 exit
Create the appropriate vlans
vlan create 4 name IPMI type port vlan create 9 name FARMNET type port vlan configcontrol automatic vlan members remove 1 1-48 vlan ports 1-46 tagging disable vlan ports 47-48 tagging enable vlan ports 47-48 tagging tagAll vlan members 9 1-46 vlan members add 4 47-48 vlan members add 9 47-48
Configure the proper type of trunking:
no mlt 1 int FastEthernet 47-48 lacp aggregation port 47-48 enable lacp mode port 47-48 active exit
The management interface of the switch can be assigned to VLAN4 now and then configured with the ip address of the switch using:
vlan mgmt 4 ip address 172.20.1.YYY ip address netmask 255.255.0.0 ip default-gateway 172.20.255.254
where
farmnet-sw-valentine-01.ipmi.nikhef.nl | 172.20.1.248 |
farmnet-sw-valentine-02.ipmi.nikhef.nl | 172.20.1.249 |
farmnet-sw-valentine-03.ipmi.nikhef.nl | 172.20.1.250 |
farmnet-sw-valentine-01S.ipmi.nikhef.nl | 172.20.1.245 |
farmnet-sw-valentine-02S.ipmi.nikhef.nl | 172.20.1.246 |
farmnet-sw-valentine-03S.ipmi.nikhef.nl | 172.20.1.247 |
Try and save the configuration:
exit copy config nvram
and check the LACP status with
sho lacp debug member 47-48
Deel configuration
The link aggregation group on deel should also be LACP (802.3ad, i.e., dynamic)
lag "farmnet-sw-valentine-01" dynamic ports e 13/3 to 13/4 primary-port 13/3 deploy port-name "farmnet-sw-valentine-01-A" ethernet 13/3 port-name "farmnet-sw-valentine-01-A" ethernet 13/4 exit
lag "farmnet-sw-valentine-02" dynamic ports e 13/5 to 13/6 primary-port 13/5 deploy port-name "farmnet-sw-valentine-02-A" ethernet 13/5 port-name "farmnet-sw-valentine-02-A" ethernet 13/6 exit
lag "farmnet-sw-valentine-03" dynamic ports e 13/11 to 13/12 primary-port 13/11 deploy port-name "farmnet-sw-valentine-03-A" ethernet 13/11 port-name "farmnet-sw-valentine-03-A" ethernet 13/12 exit
and update the cricket configuration ...