ITk Endcap At Nikhef
The construction of the ITk Strip End-caps at Nikhef. Contents author: Andrea García Alonso (aalonso@nikhef.nl)
Wheels
Wheel conduction after assembly
Wheel and Blade production documentation & characterisation
Wheel and Blade production documentation & characterisation
Wheel locking point measurements
Wheel locking point measurements
Wheel QA/QC
Inner ring measurements
Stiffening disk
The stiffening disks of the End-caps, made of Ultem foam with a carbon-fiber face-sheet, were produced and tested at Nikhef. The stiffening disks provide structural stiffness to the EC and act as a thermal barrier. To certify that the three manufactured stiffening disks comply with the specifications, an ATLAS internal note was written to explain the thermal deformation tests carried out at Nikhef, at the end of 2021 and the beginning of 2022. Although it is quite difficult to measure small thermal deformations on such big structures, three tests were performed: temperature changes, local temperature gradients, and global temperature gradients. The results show that the deformations in two disks are consistent with the specifications. The remaining disk is chosen as spare since it deforms above expected, although still mechanically acceptable.
File:ATL-COM-ITK-2022-064.pdf
You can find the ATLAS internal note called "Temperature deformation tests of the ITk strip end-cap stiffening disks produced at Nikhef" here: https://cds.cern.ch/record/2824857. In case you don't have access, please contact Andrea García Alonso.
Cooling manifolds
The ITk strip End-cap detector consists of 6 wheels that each accommodate 32 petals. The petals are cooled with a 2-phase CO2 system using cooling service modules that serve 16 petals, corresponding to half a wheel.
Status on 1st June 2023:
Disk 0 manifolds fabrication is not finished
All manifolds for disk 1 and disk 2 are fabricated, the As and Bs for disk 3 are fabricated as well. Disk 2, outlet manifolds A, B, C and D are cleaned by 31st May 2023.
Summer 2023: Pressure tests + leak tests + alcohol flushing
Every manifold is tested at a high pressure (170 bar) and a check for leaks is performed using Helium. Afterwards, every manifold is internally cleaned with alcohol to assure that no small particles could eventually block the capillarities to which the manifold will be connected.
Test reports and status available here:
Inlet
manifold |
Produced | Preassure
tested |
Leak
tested |
Alcohol
flushed |
Ready for
installation |
Outlet
manifold |
Produced | Preassure
tested |
Leak
tested |
Alcohol
flushed |
Ready for
installation | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Disk 0 - A | ✓ | ✓ | ✓ | ✓ | YES | Disk 0 - A | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 0 - B | ✓ | ✓ | ✓ | ✓ | YES | Disk 0 - B | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 0 - C | ✓ | ✓ | ✓ | ✓ | YES | Disk 0 - C | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 0 - D | ✓ | ✓ | ✓ | ✓ | YES | Disk 0 - D | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 1 - A | ✓ | ✓ | ✓ | ✓ | YES | Disk 1 - A | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 1 - B | ✓ | ✓ | ✓ | ✓ | YES | Disk 1 - B | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 1 - C | ✓ | ✓ | ✓ | ✓ | YES | Disk 1 - C | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 1 - D | ✓ | ✓ | ✓ | ✓ | YES | Disk 1 - D | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 2 - A | ✓ | ✓ | ✓ | ✓ | YES | Disk 2 - A | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 2 - B | ✓ | ✓ | ✓ | ✓ | YES | Disk 2 - B | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 2 - C | ✓ | ✓ | ✓ | ✓ | YES | Disk 2 - C | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 2 - D | ✓ | ✓ | ✓ | ✓ | YES | Disk 2 - D | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 3 - A | ✓ | ✓ | ✓ | ✓ | YES | Disk 3 - A | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 3 - B | ✓ | ✓ | ✓ | ✓ | YES | Disk 3 - B | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 3 - C | ✓ | ✓ | ✓ | ✓ | YES | Disk 3 - C | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 3 - D | ✓ | ✓ | ✓ | ✓ | YES | Disk 3 - D | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 4 - A | ✓ | ✓ | ✓ | ✓ | YES | Disk 4 - A | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 4 - B | ✓ | ✓ | ✓ | ✓ | YES | Disk 4 - B | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 4 - C | ✓ | ✓ | ✓ | ✓ | YES | Disk 4 - C | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 4 - D | ✓ | ✓ | ✓ | ✓ | YES | Disk 4 - D | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 5 - A | ✓ | ✓ | ✓ | ✓ | YES | Disk 5 - A | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 5 - B | ✓ | ✓ | ✓ | ✓ | YES | Disk 5 - B | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 5 - C | ✓ | ✓ | ✓ | ✓ | YES | Disk 5 - C | ✓ | ✓ | ✓ | ✓ | YES | |
Disk 5 - D | ✓ | ✓ | ✓ | ✓ | YES | Disk 5 - D | ✓ | ✓ | ✓ | ✓ | YES |
PP1 patch panel
Plan for QA/QC during 2024
- Tcycle a piece between +40, -35 (or reasonably low) in a dry-air or N2 bag.
- Measure ohmic R with voltmeter on ~10 places randomly.
- Measure R between all inserts and surface. R<10 Ohm, otherwise we probably need to fix. (or are all inserts grounded anyway via their bolts).
End-cap structure
Wheel and manifold installation - Positions on ECs and numbering
The produced wheels have been installed in the two end-caps as shown in the table. "EC wheel position" refers to the physical level on the EC, where 0 is the top (closest to Interaction Point IP) and 5 is the bottom (furthest from IP). "Erno number" is the identifier that was given at Nikhef to individual wheels. "Dutch-shape number" is the identifier given by the company that milled the locking points. Wheels with Erno number 1 and 14 don't belong to any EC (spare).
The inlet and outlet cooling manifolds are installed in the EC and are referred on the 4th column of the table. The pair inlet-outlet is matched according to their numbers, a.k.a. inlet manifold 1A and outlet manifold 1A are placed together, with their VCR connectors at the same location. Cooling manifolds installed close to the beam that has a corner pointing to the right (when EC standing on BH) are identified in the table as "@R beam", while those manifolds close to the beam with the corner pointing left are labeled "@L beam". Manifolds on wheel #0 will be taken away for transport to DESY, so they will have to install them again and if they follow the pattern of the rest of manifolds they will place them so all the As are together and all the Bs as well (not as it is at the moment, June 2024).
End-cap wheel
position |
Erno
number |
Dutch-shape
number |
Cooling manifolds | |
---|---|---|---|---|
@R beam | @L beam | |||
End-cap A - Wheel#0 | 11 | 19056-13-A7 | 0A | 0B |
End-cap A - Wheel#1 | 2 | 19056-15-B2 | 1B | 1A |
End-cap A - Wheel#2 | 9 | 19056-13-A3 | 2B | 2A |
End-cap A - Wheel#3 | 13 | 19056-15-b6 | 3B | 3A |
End-cap A - Wheel#4 | 7 | 19056-13-A2 | 4B | 4A |
End-cap A - Wheel#5 | 12 | 19056-15-B5 | 5B | 5A |
End-cap C - Wheel#0 | 6 | 19056-13-A1 | ||
End-cap C - Wheel#1 | 4 | 19056-15-B3 | ||
End-cap C - Wheel#2 | 10 | 19056-13-A4 | ||
End-cap C - Wheel#3 | 5 | 19056-15-B4 | ||
End-cap C - Wheel#4 | 8 | 19056-13-A6 | ||
End-cap C - Wheel#5 | 3 | 19056-13-A5 |
Wheel installation - Distances between wheel rim and lower petals
One of the QC tests in a full EC structure consists on checking the actual distances that the locking points leave between the petals and the wheel rims.
File:Lower petal-wheel rim distance EC-A.pdf
For EC-A, these are the results from the measurements of the distance between the wheel rim and the lower petal. They are also available in the wheel entries in the ITk Production database. The purpose was to check if there's enough space for the RF box. The test was done using the measurement petal, and placing it on the lowest locking points. Each measurement was performed next to a spacer rod. Important to take into account that the locking points closer to the inner cylinder might be a bit shorter than the ones on the wheel rim (sometimes the actual height would be probably 0.5mm smaller than measured).
File:Lower petal-wheel rim distance EC-C.pdf
Due to sensor cracking, one of the potential case scenarios is that the petals will get an extra layer of material, resulting in a larger petal thickness. This could be problematic if there is not enough space between the lower petals and the wheel rims in the already built EC structures (A and C). EC-A was already measured when the RF box issue was addressed, but now EC-C as well.
EC geometric measurement - Stiffness
A load of a hundred kilograms was placed inside the EC inner cylinder to mimic the operational conditions. Several 3D laser measurements indicated that the EC structures have a high stiffness leading to only 20 to 60 µm effects when loaded.
Test summary presented in the ITk week March 2024: https://indico.cern.ch/event/1353986/contributions/5865828/attachments/2822702/4929833/EC%20GEOMETRIC%20MEASUREMENT%20-%20ATLAS%20ITk%20Week%20180324.pdf
Characterization of mechanical behaviour EC structure at cold temperatures
EC structure temperature studies
Petal test box
Cleanroom at Nikhef
Miscellaneous documents
- Click here for the request regarding temporary connectors (pdf).
- ITk pictures by Jesse van Dongen
- EC mockup fb2020