Difference between revisions of "Upgrade/VeloModules"

From LHCb Wiki
Jump to navigation Jump to search
 
(11 intermediate revisions by 2 users not shown)
Line 5: Line 5:
  
 
* This wiki: https://wiki.nikhef.nl/lhcb/Upgrade/VeloModules
 
* This wiki: https://wiki.nikhef.nl/lhcb/Upgrade/VeloModules
 +
* gitlab for module production: https://gitlab.cern.ch/velo-upgrade-module0-documentation
 
* ELOG: https://webapps.nikhef.nl/elog/VELO_Upgrade_Cooling_VELOpix/
 
* ELOG: https://webapps.nikhef.nl/elog/VELO_Upgrade_Cooling_VELOpix/
 +
* zoom: https://cern.zoom.us/j/98687873748?pwd=UXVOMXJaSHJZZlVVVDY5Z01LT2pWQT09
 +
* google documents:
 +
  * production status: https://docs.google.com/spreadsheets/d/1aQUv3_9Cp1Wo5tmCbe4lyL7TXjcZVb4F1SLHjV4-ZqY
 +
  * module status: https://docs.google.com/document/d/1hnCGsmCTcDe4o2m7lTcTWRrB2gXco2-zq2ImWTs1_b8
 
* Progress reports in MT meetings: http://www.nikhef.nl/pub/experiments/bfys/lhcb/vertex/documents/minutes/
 
* Progress reports in MT meetings: http://www.nikhef.nl/pub/experiments/bfys/lhcb/vertex/documents/minutes/
 
* OPP reports: http://www.nikhef.nl/pub/experiments/bfys/lhcb/vertex/documents/oppreports/VeloUpgradeModules/
 
* OPP reports: http://www.nikhef.nl/pub/experiments/bfys/lhcb/vertex/documents/oppreports/VeloUpgradeModules/
Line 14: Line 19:
 
== Documentation ==
 
== Documentation ==
  
* project plans: [http://www.nikhef.nl/pub/experiments/bfys/lhcb/vertex/documents/projects/VeloUpgradeModules/LHCb_ModuleProduction4VELO.Upgrade_2016_plan.160201.pdf 2016]
+
* [http://www.nikhef.nl/pub/experiments/bfys/lhcb/vertex/documents/projects/VeloUpgradeModules/VeloModules-PPF-Sep2016.docx Project Fact Sheet]
* timeline (gantt chart): [http://www.nikhef.nl/pub/experiments/bfys/lhcb/vertex/documents/projects/VeloUpgradeModules/VeloModulesTimeline20160908.pdf 2016]
+
* [http://www.nikhef.nl/pub/experiments/bfys/lhcb/vertex/documents/projects/VeloUpgradeModules/LHCb_ModuleProduction4VELO.Upgrade_2016tm2019_plan.160131.docx project plan]
 +
* [http://www.nikhef.nl/pub/experiments/bfys/lhcb/vertex/documents/projects/VeloUpgradeModules/VeloModulesTimeline20160908.pdf timeline] (gantt chart)
  
 
== Setup for module production QA (last update 22/9/2016) ==
 
== Setup for module production QA (last update 22/9/2016) ==
Line 53: Line 59:
 
'''Information for cooling and test location decision:'''
 
'''Information for cooling and test location decision:'''
 
* Ground plan N025 & H026: [http://www.nikhef.nl/pub/departments/mt/projects/lhcb-vertex/VELOupgrade/Plattegronden_N025&H026.pdf N025&H026]
 
* Ground plan N025 & H026: [http://www.nikhef.nl/pub/departments/mt/projects/lhcb-vertex/VELOupgrade/Plattegronden_N025&H026.pdf N025&H026]
* List of pros and cons (dutch: [http://www.nikhef.nl/pub/departments/mt/projects/lhcb-vertex/VELOupgrade/Voordelen&nadelen.pdf List]
+
* List of pros and cons (dutch): [http://www.nikhef.nl/pub/departments/mt/projects/lhcb-vertex/VELOupgrade/Voordelen&nadelen.pdf List]
  
 
=== Schedule / action list ===
 
=== Schedule / action list ===
Line 62: Line 68:
 
* configure the PC for LV and HV controls (Q1 2017? does this make sense if we do not have a module yet?)
 
* configure the PC for LV and HV controls (Q1 2017? does this make sense if we do not have a module yet?)
 
* prepare DAQ system (Q1 2017)
 
* prepare DAQ system (Q1 2017)
 +
 +
=== Recent presentations in module-0 meeting ===
 +
 +
* Wouter 14/10/2016 https://indico.cern.ch/event/487184/contributions/2340517/
 +
* Wouter 17/01/2017 https://indico.cern.ch/event/602994/contributions/2440570/
 +
* Freek, 7/3/2017 https://indico.cern.ch/event/605171/contributions/2508169/
 +
* Freek, 31/01/2017 https://indico.cern.ch/event/605166/contributions/2461509/
 +
* Freek, 10/01/2017 https://indico.cern.ch/event/598997/contributions/2427915/
 +
* Freek, 27/6/2017 https://indico.cern.ch/event/643148/
 +
* Wouter 11/7/2017 https://indico.cern.ch/event/643150/
 +
* Jesse, 25/7/2017 https://indico.cern.ch/event/643152/
 +
* Freek, 1/8/2017 https://indico.cern.ch/event/643153/
 +
* Freek, 8/8/2017 https://indico.cern.ch/event/643154/
 +
* Freek, 15/8/2017 https://indico.cern.ch/event/643155/

Latest revision as of 09:49, 8 February 2021

Under construction


Communication

 * production status: https://docs.google.com/spreadsheets/d/1aQUv3_9Cp1Wo5tmCbe4lyL7TXjcZVb4F1SLHjV4-ZqY
 * module status: https://docs.google.com/document/d/1hnCGsmCTcDe4o2m7lTcTWRrB2gXco2-zq2ImWTs1_b8

Documentation

Setup for module production QA (last update 22/9/2016)

There are two tests:

1. quick electrical test ("20 seconds"), mainly to check that wirebonds are ok. This test should take place in the clean-room. For this we need:

  • LV (incl. PC for controls?)
  • DAQ
  • fibers to connect to DAQ
  • database to summarize results

2. burn-in test ("24 hours"). For this we need:

  • LV
  • HV (till 1000V; must have precise current control/monitor )
  • PC with PVSS to control LV and HV
  • DAQ
  • fibers to connect to DAQ
  • PC to run data analysis (needs to happen in real time as data volumes are very large)
  • database to summarize results
  • 19 inch rack
  • CO2 cooling
  • vacuum tank
  • if not in the cleanroom, a 'tent' to protect setup

DAQ system

We will have only one DAQ system, the so-called 'mini-DAQ'. A system consists of a PCI express card in an ASUS ESC 4000 G3 server PC. (See https://www.asus.com/us/Commercial-Servers-Workstations/ESC4000_G3/). As we have only one system, we either need to do both tests in the same place, or pull fibers.

CO2 Cooling

A lot of what we do depends on where we do test 2. If we do it in the clean room, then we need a blow system for the CO2. If we do it in the vacuum lab, then we need to pull a lot of optical fibers. To take this decision, we need to understand:

  • when is the blow system available? how often do we need to change bottles? is bottled CO2 dry and clean enough? is a blow system with cryogenic CO2 an option?
  • is the standard CO2 cooler reliable enough?

Information for cooling and test location decision:

  • Ground plan N025 & H026: N025&H026
  • List of pros and cons (dutch): List

Schedule / action list

Things that we can prepare before the decision on the location of test 2:

  • finish the vacuum tank (Q4 2016)
  • collect LV and HV units, 19 inch rack (Q4 2016)
  • configure the PC for LV and HV controls (Q1 2017? does this make sense if we do not have a module yet?)
  • prepare DAQ system (Q1 2017)

Recent presentations in module-0 meeting