| cooling aggregate || CU201 || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/ECR-010407-offerte-nikhef-1.pdf ECR_Danfoss] || N || frequency controlled aggregate /  [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/ECR-010407-ALfaLaval-CB27-20H.rtf Condenser sizing]
 
| cooling aggregate || CU201 || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/ECR-010407-offerte-nikhef-1.pdf ECR_Danfoss] || N || frequency controlled aggregate /  [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/ECR-010407-ALfaLaval-CB27-20H.rtf Condenser sizing]
 
|-
 
|-
| heater || HT110 || N || make sure it is a sealed version
+
| heater || HT110 || || N || make sure it is a sealed version
 
|-  
 
|-  
 
| heat exchanger || HXxxx || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/AXP10.pdf AXP10] [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/AXP10_20H_F_20101007091810826-1.pdf CO2-R404A] [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/AXP10_10H_F_selecties_nikhef-4.pdf CO2-CO2 ] || N || can test to 1.44*Pmax
 
| heat exchanger || HXxxx || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/AXP10.pdf AXP10] [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/AXP10_20H_F_20101007091810826-1.pdf CO2-R404A] [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/AXP10_10H_F_selecties_nikhef-4.pdf CO2-CO2 ] || N || can test to 1.44*Pmax

Revision as of 10:11, 28 October 2010

General

Project plan / Specifications

Safety classes for a 90bar pressure vessel

Conceptual Design

XFEL cooler schematics and Controls

Primary circuit test setup Schematics for ECR

XFEL cooler controls

Calculations

Tube diameters

Accumulator size

Accumulator spiral

Heat Exchanger properties

Components

component ID information drawing comment
control valve VL20x Danfoss UKV10D85 / UKV18D02 Control Unit N proportional control valve
cooling aggregate CU201 ECR_Danfoss N frequency controlled aggregate / Condenser sizing
heater HT110 N make sure it is a sealed version
heat exchanger HXxxx AXP10 CO2-R404A CO2-CO2 N can test to 1.44*Pmax
flow sensor FT103 RHM03 NL083183 Y flow to 1kg/min / different resonance freq. than RHM015 / can provide PED documents
flow transmitter FT103 RHE14 Y together with flow sensor
valve handle extension N/A Valve extender N
2-way valve VL118 SS-43GHLVCR4 Y on-off valve with VCR connections / HL option = T form inside ball
3-way valve VL103, VL105, VL111 SS-43GXLVCR4 Y 3-way valve with L pattern
pressure transmitter PT1xx PTX5072-TC-A2-CA-H0-PE 0-100bar abs N GE sensing new product line / can provide conformity document
temperature sensor TT1xxx 2ABi15-230mm/ti/mf9/2AB25.nn/2meter N Thermocoax
pump body PM101 Varicon N
pump head PM101 1M-J/12/11/X-SS/S/Q/K200/DLC N compatible with CO2 / ask for PED documents
relieve valve PR1xx N

Electronics

Drawings

Flow transmitter RHE14

Flowsensor+fitting

Assy_VL43g_2-way_valve_extention_short

Assy_VL43g_2-way_valve_extension_short_BOM

Assy_VL43g_2-way_valve_extension_long

Assy_VL43g_2-way_valve_extension_long_BOM

Assy_VL43g_1_4In_VCR_electrical_ball_valve_short_BOM

Assy_VL43g_1_4In_VCR_electrical_ball_valve_short

Assy_VL43g_1_4In_VCR_manual_ball_valve_short_BOM

Assy_VL43g_1_4In_VCR_manual_ball_valve_short

Assy_VL43g_1_4In_VCR_manual_ball_valve_long_BOM

Assy_VL43g_1_4In_VCR_manual_ball_valve_long

Assy_VL43g_1_4In_VCR_electrical_ball_valve_long_BOM

Assy_VL43g_1_4In_VCR_electrical_ball_valve_long

Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_short_BOM

Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_short

Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_long_BOM

Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_long

Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_short_BOM

Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_short

Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_long_BOM

Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_long