Line 21: Line 21:
 
|-
 
|-
 
| cryostat || Julabo || find out dimensions
 
| cryostat || Julabo || find out dimensions
 +
|-
 +
| heater || ||
 
|-  
 
|-  
 
| heat exchanger || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/PCT00128EN_CBXP27.pdf CBXP27]  [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/AXP10.pdf AXP10]|| can test to 1.44*Pmax / must choose number of plates
 
| heat exchanger || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/PCT00128EN_CBXP27.pdf CBXP27]  [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/AXP10.pdf AXP10]|| can test to 1.44*Pmax / must choose number of plates

Revision as of 15:50, 10 September 2010

General

Project plan / Specifications

Safety classes for a 90bar pressure vessel

Schematics

XFEL cooler schematics

Calculations

Accumulator size

Components

component information comment
control valve Danfoss EVRST10 used in current plant: good again?
cryostat Julabo find out dimensions
heater
heat exchanger CBXP27 AXP10 can test to 1.44*Pmax / must choose number of plates
flow sensor RHM03 NL083183 flow to 1kg/min / low dP / can provide PED documents
flow transmitter RHE14 together with flow sensor
manual 2-way valve SS-43GHLVCR4 on-off valve with VCR connections / HL option = T form inside ball
manual 3-way valve SS-43GXLVCR4 3-way valve with L pattern
pressure transmitter PTX5072-TC-A2-CA-H0-PE 0-100bar abs GE sensing new product line / can provide conformity document
temperature sensor
pump body Varicon need profibus interface
pump head 1M-J/12/11/X-SS/S/Q/K200/DLC compatible with CO2 / ask for PED documents
relieve valve

Electronics