Difference between revisions of "XFELCooler"

From Atlas Wiki
Jump to navigation Jump to search
Line 24: Line 24:
 
| flow meter || ||
 
| flow meter || ||
 
|-
 
|-
| manual valve || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/MS-01-146.pdf SS-42GVCR4-HL]  || on-off valve with VCR connections / HL option = T form inside ball
+
| manual valve || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/MS-01-146.pdf SS-43GVCR4-HL]  || on-off valve with VCR connections / HL option = T form inside ball
 
|-
 
|-
 
| pressure transmitter || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/920-483D-LR.pdf PTX50xx]  || GE sensing new product line / can provide conformity document
 
| pressure transmitter || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/920-483D-LR.pdf PTX50xx]  || GE sensing new product line / can provide conformity document

Revision as of 17:01, 1 September 2010

General

Project plan / Specifications

Safety classes for a 90bar pressure vessel

Schematics

XFEL cooler schematics

Calculations

Components

component information comment
control valve
cryostat
heat exchanger CBXP27 made for CO2 applications / 90bar max operating pressure / test to 1.44*90bar / must choose number of plates
flow meter
manual valve SS-43GVCR4-HL on-off valve with VCR connections / HL option = T form inside ball
pressure transmitter PTX50xx GE sensing new product line / can provide conformity document
pt100
pump

Electronics

Drawings