Aod ntuple

From Atlas Wiki
Jump to navigation Jump to search

This page contains basic prescriptions to get physics objects from the AOD and the AOD-based Root ntuple.

Some comments on quality selection cuts will be added as work progresses.


Electron

There are 3 types of quality cuts you can perform on the electron candidates:

  1. Cuts based eID
  2. Likelihood based eID
  3. NeuralNet based eID

- alg 1 used both calorimeter and tracking information in addition to TRT information. In 9.0.4 there is a problem with TRT simulation so one has to mask TRT bit to recover the lost efficiency. The variable which combine everything is isEM and it is used as follow:

elec*->isEM()

to mask TRT bit you should use: elec*->isEM()%16==0

if you use isEM then you will select electrons with an overall eff of about 80% in the barrel but much lower in the crack and endcup.


-alg 2 use likelihood ratio and use the following variable:

energy in different calorimeter sampling, shower shapes in both eta and phi and E/P. No TRT information is used here. You need to access two variables called emweight and pionweight then you can construct the likelihood ratio: defined by: emweight/(emweight+pionweight). Emweight is the product of pdf's for electrons and pionweight is the product of pdf's for pions. In AOD, you use the following code:

ElecEMWeight = elec*->parameter(ElectronParameters::emWeight); ElecPiWeight = elec*->parameter(ElectronParameters::pionWeight);

Then form the variable: X = ElecEMWeight/(ElecEMWeight+ElecPiWeight)

Requiring X > 0.6 will give you more than 90% eff for electrons


-alg 3 use the NeuralNet and use as inputs the same variables used for likelihood. To use it in AOD you should proceed as follow:

ElecepiNN = elec*->parameter(ElectronParameters::epiNN);

Requiring ElecepiNN > 0.6 will give you about 90% eff for electrons.

However, you should be aware that the ANN was trained in full eta range while the likelihood was computed in 3 bins in eta: barrel, crack and endcup. So I would suggest to use likelihood for now. I am working on improving things but it will not be ready for Rome. For sure using likelihood will give you 90% eff for electrons with a good jet rejection.

Muon

Tau

Jet

BJet

Missing Et

External References