Aod ntuple
This page contains basic prescriptions to get physics objects from the AOD and the AOD-based Root ntuple.
Some comments on quality selection cuts will be added as work progresses.
Electron
| AOD Container Name | AOD Variable | Ntuple Variable | Variable Type | Comment | ||
| ElectronCollection | ||||||
| n_elec | Int | Number of electrons in the Ntuple | ||||
| px_elec | Double | Px | ||||
| py_elec | Double | Py | ||||
| pz_elec | Double | Pz | ||||
| pt_elec | Double | Pt | ||||
| eta_elec | Double | Eta | ||||
| phi_elec | Double | Phi | ||||
| isem_elec | Int | isEMflag (see below) | ||||
| hastrk_elec | Int (bool) | HasTrackflag: presence of charged track in the Inner Detector | ||||
| z0vtx_elec | Double | Intersection (z) of track with the beam axis | ||||
| d0vtx_elec | Double | Transverse impact paramter d0 | ||||
| nblayerhits_elec | Int | Number of hits in the Pixel B-layer | ||||
| npixelhits_elec | Int | Number of hits in the Pixel detector | ||||
| nscthits_elec | Int | Number of hits in the SCT | ||||
| ntrthits_elec | Int | Number of hits in the TRT | ||||
| ntrththits_elec | Int | Number of high threshold hits in the TRT | ||||
| auth_elec | Int??? | Algorithm used to create the electron: softeoregamma | ||||
| eoverp_elec | Double | E/P ratio | ||||
| etcone_elec | Double | Energy deposition in a cone dR=0.45 around the electron cluster | ||||
| etcone20_elec | Double | Energy deposition in a cone dR=0.20 around the electron cluster. Standard cone size for ATLFAST | ||||
| etcone30_elec | Double | Energy deposition in a cone dR=0.30 around the electron cluster. Currently empty | ||||
| etcone40_elec | Double | Energy deposition in a cone dR=0.40 around the electron cluster | ||||
| emwgt_elec | Double | Weight for electrons (see below) | ||||
| piwgt_elec | Double | Weight for pions (see below) | 
There are 3 types of quality cuts you can perform on the electron candidates:
- Cuts based on the isEMflag
- Cuts based on likelihood
- Cuts based on NeuralNet output
1.
The isEM flag uses both calorimeter and tracking information in addition to TRT
information. The flag is a bit field which marks whether the candidate passed or not some safety checks.
The bit field marks the following checks:
  Cluster based egamma
  ClusterEtaRange        =  0,
  ClusterHadronicLeakage =  1,
  ClusterMiddleSampling  =  2,
  ClusterFirstSampling   =  3,
  Track based egamma
  TrackEtaRange          =  8,
  TrackHitsA0            =  9,
  TrackMatchAndEoP       = 10,
  TrackTRT               = 11
In 9.0.4 there is a problem with TRT simulation so one has to mask TRT bit to recover the lost efficiency.
To get the flag in your AOD analysis you should use:
(*elec)->isEM()
To mask the TRT bits you should use: (*elec)->isEM()&0x7FF==0
If you use isEM then you will select electrons with an overall efficiency of about
80% in the barrel but much lower in the crack and endcap.
2.
The likelihood ratio is constructed using the following variables: energy in different calorimeter samplings, shower shapes in both eta and phi and E/P ration. No TRT information is used here.
You need to access two variables called emweight and pionweight then you can construct the likelihood ratio, defined by: emweight/(emweight+pionweight). 
In AOD, you use the following code:
ElecEMWeight = elec*->parameter(ElectronParameters::emWeight);
ElecPiWeight = elec*->parameter(ElectronParameters::pionWeight);
Then form the variable:
X = ElecEMWeight/(ElecEMWeight+ElecPiWeight);
Requiring X > 0.6 will give you more than 90% efficiency for electrons.
3.
The NeuralNet variable uses as inputs the same variables used for likelihood. To use it in AOD you should proceed as follow:
ElecepiNN = elec*->parameter(ElectronParameters::epiNN);
Requiring ElecepiNN > 0.6 will give you about 90% eff for electrons.
However, you should be aware that the NN was trained in full eta range while the likelihood was computed in 3 bins in eta: barrel, crack and endcap. So I would suggest to use likelihood for now.