General
Safety classes for a 90bar pressure vessel
Conceptual Design
XFEL cooler schematics and Controls Schematics for PLC
Primary circuit test setup Schematics for ECR
Calculations
Components
| component | ID | information | drawing | comment |
|---|---|---|---|---|
| control valve | VL20x | Danfoss UKV10D85 / UKV18D02 Control Unit | N | proportional control valve |
| cooling aggregate | CU201 | ECR_Danfoss | N | frequency controlled aggregate / Condenser sizing |
| heater | HT110 | N | make sure it is a sealed version | |
| heat exchanger | HXxxx | AXP10 CO2-R404A CO2-CO2 | N | can test to 1.44*Pmax |
| flow sensor | FT103 | RHM03 NL083183 | Y | flow to 1kg/min / different resonance freq. than RHM015 / can provide PED documents |
| flow transmitter | FT103 | RHE14 | Y | together with flow sensor |
| valve handle extension | N/A | Valve extender | N | |
| 2-way valve | VL118 | SS-43GHLVCR4 | Y | on-off valve with VCR connections / HL option = T form inside ball |
| 3-way valve | VL103, 105, 111 | SS-43GXLVCR4 | Y | 3-way valve with L pattern |
| pressure transmitter | PT1xx | PTX5072-TC-A2-CA-H0-PE 0-100bar abs | N | GE sensing new product line / can provide conformity document |
| temperature sensor | TT1xx | 2ABi15-230mm/ti/mf9/2AB25.nn/2meter | N | Thermocoax |
| pump body | PM101 | Varicon | N | |
| pump head | PM101 | 1M-J/12/11/X-SS/S/Q/K200/DLC | N | compatible with CO2 / ask for PED documents |
| relieve valve | PR1xx | N |