Difference between revisions of "XFELCooler"
Jump to navigation
Jump to search
Line 20: | Line 20: | ||
| cryostat || || | | cryostat || || | ||
|- | |- | ||
− | | heat exchanger || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/PCT00128EN_CBXP27.pdf CBXP27] || made for CO2 applications / 90bar max operating pressure / test to 1.44*90bar | + | | heat exchanger || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/PCT00128EN_CBXP27.pdf CBXP27] || made for CO2 applications / 90bar max operating pressure / test to 1.44*90bar / must choose number of plates |
|- | |- | ||
| flow meter || || | | flow meter || || |
Revision as of 12:56, 1 September 2010
General
Safety classes for a 90bar pressure vessel
Schematics
Calculations
Components
component | information | comment |
---|---|---|
control valve | ||
cryostat | ||
heat exchanger | CBXP27 | made for CO2 applications / 90bar max operating pressure / test to 1.44*90bar / must choose number of plates |
flow meter | ||
manual valve | SS-42GVCR4-HL | on-off valve with VCR connections / HL option = T form inside ball |
pressure transmitter | ||
PT100 | PTX50xx | GE sensing new product line / can provide conformity document |
pump |