Difference between revisions of "XFELCooler"
Jump to navigation
Jump to search
Line 51: | Line 51: | ||
| temperature sensor || || N || | | temperature sensor || || N || | ||
|- | |- | ||
− | | pump body || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/GearPump_body_SUURMOND.pdf Varicon] || N || | + | | pump body || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/GearPump_body_SUURMOND.pdf Varicon] || N || |
|- | |- | ||
| pump head || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/GearPump_head_SUURMOND.pdf 1M-J/12/11/X-SS/S/Q/K200/DLC] || N || compatible with CO2 / ask for PED documents | | pump head || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/GearPump_head_SUURMOND.pdf 1M-J/12/11/X-SS/S/Q/K200/DLC] || N || compatible with CO2 / ask for PED documents |
Revision as of 10:43, 21 October 2010
General
Safety classes for a 90bar pressure vessel
Conceptual Design
XFEL cooler schematics and Controls
Primary circuit test setup Schematics for ECR
Calculations
Components
component | information | drawing | comment |
---|---|---|---|
control valve | Danfoss UKV10D85 Control Unit | N | proportional control valve |
cooling aggregate | ECR_Danfoss | N | frequency controlled aggregate / Condenser sizing |
heater | N | make sure it is a sealed version | |
heat exchanger | AXP10 CO2-R404A CO2-CO2 | N | can test to 1.44*Pmax |
flow sensor | RHM03 NL083183 | Y | flow to 1kg/min / different resonance freq. than RHM015 / can provide PED documents |
flow transmitter | RHE14 | Y | together with flow sensor |
valve handle extension | Valve extender | N | |
manual 2-way valve | SS-43GHLVCR4 | Y | on-off valve with VCR connections / HL option = T form inside ball |
manual 3-way valve | SS-43GXLVCR4 | Y | 3-way valve with L pattern |
pressure transmitter | PTX5072-TC-A2-CA-H0-PE 0-100bar abs | N | GE sensing new product line / can provide conformity document |
temperature sensor | N | ||
pump body | Varicon | N | |
pump head | 1M-J/12/11/X-SS/S/Q/K200/DLC | N | compatible with CO2 / ask for PED documents |
relieve valve | N |
Electronics
Drawings
VL43g_Valve_side_locking_plate