Difference between revisions of "XFELCooler"

From Atlas Wiki
Jump to navigation Jump to search
Line 16: Line 16:
 
! component || information || comment
 
! component || information || comment
 
|-
 
|-
| control valve || ||
+
| control valve || Danfoss || find out dimensions
 
|-
 
|-
 
| cryostat || ||
 
| cryostat || ||

Revision as of 11:47, 3 September 2010

General

Project plan / Specifications

Safety classes for a 90bar pressure vessel

Schematics

XFEL cooler schematics

Calculations

Components

component information comment
control valve Danfoss find out dimensions
cryostat
heat exchanger CBXP27 made for CO2 applications / 90bar max operating pressure / test to 1.44*90bar / must choose number of plates
flow sensor RHM03 NL083183 flow to 1kg/min / low dP / can provide PED documents
flow transmitter RHE14 together with flow sensor
manual 2-way valve SS-43GHLVCR4 on-off valve with VCR connections / HL option = T form inside ball
manual 3-way valve SS-43GXLVCR4 3-way valve with L pattern
pressure transmitter PTX5072-TC-A2-CA-H0-PE 0-100bar abs GE sensing new product line / can provide conformity document
pt100
pump
relieve valve

Electronics

Drawings