Difference between revisions of "XFELCooler"
Jump to navigation
Jump to search
(13 intermediate revisions by the same user not shown) | |||
Line 13: | Line 13: | ||
[http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Schematics/ECRaddition.pdf Schematics for ECR] | [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Schematics/ECRaddition.pdf Schematics for ECR] | ||
− | [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Schematics/ | + | [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Schematics/CO2_XFEL_Controls_v3.0.pdf XFEL cooler controls] |
== Calculations == | == Calculations == | ||
Line 29: | Line 29: | ||
|- | |- | ||
! component || ID || information || drawing || comment | ! component || ID || information || drawing || comment | ||
+ | |- | ||
+ | | accumulator || AC101 ||[http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/AC101/AC101_Hoefnagel.pdf Drawings] || Y|| by Hoefnagel & Meijn | ||
|- | |- | ||
| burst disk || PR1xx || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/Swagelok_SS-RDK-16-1900.pdf SS-RDK-16-1900] || N || 130bar burst | | burst disk || PR1xx || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/Swagelok_SS-RDK-16-1900.pdf SS-RDK-16-1900] || N || 130bar burst | ||
Line 36: | Line 38: | ||
| control valve || VL20x || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/CAREL_E2V_030220815.pdf Carel E2V] [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/CAREL_EVD_0300006EN.pdf Control unit] || N || proportional control valve | | control valve || VL20x || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/CAREL_E2V_030220815.pdf Carel E2V] [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/CAREL_EVD_0300006EN.pdf Control unit] || N || proportional control valve | ||
|- | |- | ||
− | | cooling aggregate || CU201 || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/FRCC-PC-009-A1-02.pdf VTZ038 compressor] [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/MANUAL_vtz_Danfoss.pdf Frequency controller] || N || ECR condensing unit | + | | cooling aggregate || CU201 || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/FRCC-PC-009-A1-02.pdf VTZ038 compressor] [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/MANUAL_vtz_Danfoss.pdf Frequency controller] || N || ECR condensing unit [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/CU201/KoeltechnischSchema.pdf Koeltechnisch schema] [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/CU201/ElectrischSchema_A1.pdf Electrisch schema] |
|- | |- | ||
| filter || FT103 || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/Swagelok_ss-4TF-TW-15.pdf SS-4TF-TW-15] || N || | | filter || FT103 || [http://www.nikhef.nl/pub/experiments/atlas/co2/xfel/Components/Swagelok_ss-4TF-TW-15.pdf SS-4TF-TW-15] || N || | ||
Line 131: | Line 133: | ||
|- | |- | ||
|} | |} | ||
+ | |||
+ | == Pictures == | ||
+ | |||
+ | [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Pictures/IMG_4415.JPG Heatexchanger] | ||
+ | |||
+ | [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Pictures/IMG_4414.JPG Heatexchanger] | ||
+ | |||
+ | [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Pictures/IMG_4413.JPG Pipesections] | ||
+ | |||
+ | [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Pictures/IMG_4654.JPG heatexchaner bracket] | ||
+ | |||
+ | [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Pictures/IMG_4657.JPG Vaccumpumpplate] | ||
+ | |||
+ | [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Pictures/IMG_4656.JPG Midsectionplate] | ||
+ | |||
+ | [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Pictures/IMG_4658.JPG Buttomplate] | ||
+ | |||
+ | [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Pictures/IMG_4655.JPG The Frame] | ||
+ | |||
+ | [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Pictures/IMG_4659.JPG The frame2] |
Latest revision as of 14:41, 25 March 2011
General
Qualification of ClassII cooler
Conceptual Design
XFEL cooler schematics and Controls Schematics for PLC
Primary circuit test setup Schematics for ECR
Calculations
Components
component | ID | information | drawing | comment |
---|---|---|---|---|
accumulator | AC101 | Drawings | Y | by Hoefnagel & Meijn |
burst disk | PR1xx | SS-RDK-16-1900 | N | 130bar burst |
check valve | VL103 | 6L-CW4VR4 | N | one way valve |
control valve | VL20x | Carel E2V Control unit | N | proportional control valve |
cooling aggregate | CU201 | VTZ038 compressor Frequency controller | N | ECR condensing unit Koeltechnisch schema Electrisch schema |
filter | FT103 | SS-4TF-TW-15 | N | |
heater | HT110 | N | make sure it is a sealed version | |
heat exchanger | HXxxx | AXP10 CO2-R404A CO2-CO2 | N | can test to 1.44*Pmax |
flow sensor | FT103 | RHM03 NL083183 | Y | flow to 1kg/min / different resonance freq. than RHM015 / can provide PED documents |
flow transmitter | FT103 | RHE14 | Y | together with flow sensor |
valve handle extension | VL105, 108 | Valve extender | Y | order with Innodry? |
2-way valve | VL108, 112 | SS-43GHLVCR4 | Y | on-off valve with VCR connections / HL option = T form inside ball |
3-way valve | VL105, 111 | SS-43GXLVCR4 | Y | 3-way valve with L pattern |
pressure transmitter | PT1xx | PTX5072-TC-A2-CA-H0-PE 0-100bar abs | Y | GE sensing new product line / can provide conformity document |
temperature sensor | TT1xx | 2ABi15-230mm/ti/mf9/2AB25.nn/2meter | N | Thermocoax |
pump body | PM101 | Varicon | Y | |
pump head | PM101 | 1M-J/12/11/X-SS/S/Q/K200/DLC | Y | compatible with CO2 / ask for PED documents |
relieve valve | PR1xx | N | ||
vacuum pump | PM111 | Vacuubrand MD1 Vacuubrand catalog | N |