Difference between revisions of "SCT DQshift"
Line 48: | Line 48: | ||
There is a finite number of defects defined for the SCT ([https://twiki.cern.ch/twiki/bin/viewauth/Atlas/SCTOfflineMonitoringShifts#DQ_Defects twiki SCT DQ defect list)] | There is a finite number of defects defined for the SCT ([https://twiki.cern.ch/twiki/bin/viewauth/Atlas/SCTOfflineMonitoringShifts#DQ_Defects twiki SCT DQ defect list)] | ||
+ | Now, check in the histograms if you understand the defects and if there are more/less than in the 'known database' database/Check if the defects are | ||
− | + | b2) click on entire run | |
+ | Check SCT and things that are not ok. | ||
'''3] Look at the histogram-summary from Tier-0 processing and sign-off the run:''' | '''3] Look at the histogram-summary from Tier-0 processing and sign-off the run:''' |
Revision as of 08:52, 13 April 2012
The minimal path through all documentation necessary for an SCT DQ shift
Goal of the shift: make sure all flags related to SCT operation are correctly stored in the database before the run is processed at the Tier-1's
General information |
---|
The Official SCT DQ shift twiki
The ATLAS data quality portal
The ATLAS detector operations page
The DQ shift |
---|
The shifter checks if the known problems are indeed present, checks for potential new ones, signs off the run and makes a summary following these steps:
1] Check the ATLAs e-Log page for (SCT-specific) information on the run
Use search form on the ATLAS e-Log page
System effected SCT ald look for run.
2] Check the known defects in the database for this run:
Start at the ATLAS DQ homepage
a) Click on Tier-0 offline
b) Select run you want
Click on 'exp[ress express' (Note if *** run is still processing)
b1) click on defect database
filter SCT and look for defects
There is a finite number of defects defined for the SCT (twiki SCT DQ defect list)
Now, check in the histograms if you understand the defects and if there are more/less than in the 'known database' database/Check if the defects are
b2) click on entire run
Check SCT and things that are not ok.
3] Look at the histogram-summary from Tier-0 processing and sign-off the run:
Look at the ES1 (express express stream pass 1) of the Tier-0 processing and check the atlasdqmhistogram-summary.
a) look for known defects:
This is the step where the real work is done: see if you can identify the known defects, look for potential new problems and 'sign off' the run.
Note:
- check box UNCHECKED (to indicated you have actually looked at the run)
- password to sign-off the run: SctDq
b)
c) sign of the run
what to do when you discover a new defect:
Send a mail to the expert. Get the name of the shifter from the ATALS OTP page (xxx missing xxx)
4] Obtain information for run-summary
Get the run summary (report, lumi and efficiencies) from the SCT DQ webtool
Use SCT-standard and use the run-number
5] Finish up: Make an entry in the ATLAS e-Log
Enter the run summary and additional comments in the e-Log on the ATLAS operations page
done