Difference between revisions of "XFELCooler"
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
	
| Line 89: | Line 89: | ||
| | 3way valve extension long || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_3-way_valve_extension_long.pdf Assy_VL43g_3-way_valve_extension_long] ||[http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_3-way_valve_extension_long_BOM.pdf Assy_VL43g_3-way_valve_extension_long_BOM]  || | | 3way valve extension long || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_3-way_valve_extension_long.pdf Assy_VL43g_3-way_valve_extension_long] ||[http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_3-way_valve_extension_long_BOM.pdf Assy_VL43g_3-way_valve_extension_long_BOM]  || | ||
| |- | |- | ||
| − | | electrical 2-way valve (S) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_electrical_ball_valve_short Assy_VL43g_1_4In_VCR_electrical_ball_valve_short] | + | | electrical 2-way valve (S) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_electrical_ball_valve_short.pdf Assy_VL43g_1_4In_VCR_electrical_ball_valve_short] | 
| − | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_electrical_ball_valve_short_BOM Assy_VL43g_1_4In_VCR_electrical_ball_valve_short_BOM] || | + | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_electrical_ball_valve_short_BOM.pdf Assy_VL43g_1_4In_VCR_electrical_ball_valve_short_BOM] || | 
| |- | |- | ||
| − | | electrical 2-way valve (L) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_electrical_ball_valve_long Assy_VL43g_1_4In_VCR_electrical_ball_valve_long] | + | | electrical 2-way valve (L) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_electrical_ball_valve_long.pdf Assy_VL43g_1_4In_VCR_electrical_ball_valve_long] | 
| − | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_electrical_ball_valve_long_BOM Assy_VL43g_1_4In_VCR_electrical_ball_valve_long_BOM] || | + | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_electrical_ball_valve_long_BOM.pdf Assy_VL43g_1_4In_VCR_electrical_ball_valve_long_BOM] || | 
| |- | |- | ||
| − | | electrical 3-way valve (S) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_short Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_short] | + | | electrical 3-way valve (S) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_short.pdf Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_short] | 
| − | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_short_BOM Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_short_BOM] || | + | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_short_BOM.pdf Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_short_BOM] || | 
| |- | |- | ||
| − | | electrical 3-way valve (L) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_long Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_long] | + | | electrical 3-way valve (L) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_long.pdf Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_long] | 
| − | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_long_BOM Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_long_BOM] || | + | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_long_BOM.pdf Assy_VL43g_1_4In_VCR_3way_electrical_ball_valve_long_BOM] || | 
| |- | |- | ||
| − | | manual 2-way valve (S) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_manual_ball_valve_short Assy_VL43g_1_4In_VCR_manual_ball_valve_short] | + | | manual 2-way valve (S) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_manual_ball_valve_short.pdf Assy_VL43g_1_4In_VCR_manual_ball_valve_short] | 
| − | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_manual_ball_valve_short_BOM Assy_VL43g_1_4In_VCR_manual_ball_valve_short_BOM] || | + | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_manual_ball_valve_short_BOM.pdf Assy_VL43g_1_4In_VCR_manual_ball_valve_short_BOM] || | 
| |- | |- | ||
| − | | manual 2-way valve (L) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_manual_ball_valve_long Assy_VL43g_1_4In_VCR_manual_ball_valve_long] | + | | manual 2-way valve (L) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_manual_ball_valve_long.pdf Assy_VL43g_1_4In_VCR_manual_ball_valve_long] | 
| − | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_manual_ball_valve_long_BOM Assy_VL43g_1_4In_VCR_manual_ball_valve_long_BOM] || | + | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_manual_ball_valve_long_BOM.pdf Assy_VL43g_1_4In_VCR_manual_ball_valve_long_BOM] || | 
| |- | |- | ||
| − | | manuall 3-way valve (S) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_short Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_short] | + | | manuall 3-way valve (S) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_short.pdf Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_short] | 
| − | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_short_BOM Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_short_BOM] || | + | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_short_BOM.pdf Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_short_BOM] || | 
| |- | |- | ||
| − | | manuall 3-way valve (L) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_long Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_long] | + | | manuall 3-way valve (L) || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_long.pdf Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_long] | 
| − | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_long_BOM Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_long_BOM] || | + | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_long_BOM.pdf Assy_VL43g_1_4In_VCR_3way_manual_ball_valve_long_BOM] || | 
| |- | |- | ||
| − | | Accumulator || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Accumulator Accumulator] || ||   | + | | Accumulator || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Accumulator.pdf Accumulator] || ||   | 
| |- | |- | ||
| | Heatexchanger AXP10-20 || HX204 || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_Heatexchanger_AXP10-20.pdf Assy_Heatexchanger_AXP10-20]   | | Heatexchanger AXP10-20 || HX204 || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_Heatexchanger_AXP10-20.pdf Assy_Heatexchanger_AXP10-20]   | ||
| Line 121: | Line 121: | ||
| || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_Heatexchanger_AXP10-10_BOM.pdf Assy_Heatexchanger_AXP10-10_BOM] || | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_Heatexchanger_AXP10-10_BOM.pdf Assy_Heatexchanger_AXP10-10_BOM] || | ||
| |- | |- | ||
| − | | Assy Gearpump || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_Gearpump Assy_Gearpump]   | + | | Assy Gearpump || N/A || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_Gearpump.pdf Assy_Gearpump]   | 
| − | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_Gearpump_BOM Assy_Gearpump_BOM] || | + | || [http://www.nikhef.nl/pub/departments/mt/projects/XFEL/Drawings/Assy_Gearpump_BOM.pdf Assy_Gearpump_BOM] || | 
| |- | |- | ||
| |} | |} | ||
Revision as of 15:00, 29 November 2010
General
Qualification of ClassII cooler
Conceptual Design
XFEL cooler schematics and Controls Schematics for PLC
Primary circuit test setup Schematics for ECR
Calculations
Components
| component | ID | information | drawing | comment | 
|---|---|---|---|---|
| burst disk | PR1xx | SS-RDK-16-1900 | N | 130bar burst | 
| check valve | VL103 | 6L-CW4VR4 | N | one way valve | 
| control valve | VL20x | Carel E2V Control unit | N | proportional control valve | 
| cooling aggregate | CU201 | VTZ038 compressor Frequency controller | N | ECR condensing unit | 
| filter | FT103 | SS-4TF-TW-15 | N | |
| heater | HT110 | N | make sure it is a sealed version | |
| heat exchanger | HXxxx | AXP10 CO2-R404A CO2-CO2 | N | can test to 1.44*Pmax | 
| flow sensor | FT103 | RHM03 NL083183 | Y | flow to 1kg/min / different resonance freq. than RHM015 / can provide PED documents | 
| flow transmitter | FT103 | RHE14 | Y | together with flow sensor | 
| valve handle extension | VL105, 108 | Valve extender | Y | order with Innodry? | 
| 2-way valve | VL108, 112 | SS-43GHLVCR4 | Y | on-off valve with VCR connections / HL option = T form inside ball | 
| 3-way valve | VL105, 111 | SS-43GXLVCR4 | Y | 3-way valve with L pattern | 
| pressure transmitter | PT1xx | PTX5072-TC-A2-CA-H0-PE 0-100bar abs | Y | GE sensing new product line / can provide conformity document | 
| temperature sensor | TT1xx | 2ABi15-230mm/ti/mf9/2AB25.nn/2meter | N | Thermocoax | 
| pump body | PM101 | Varicon | Y | |
| pump head | PM101 | 1M-J/12/11/X-SS/S/Q/K200/DLC | Y | compatible with CO2 / ask for PED documents | 
| relieve valve | PR1xx | N | ||
| vacuum pump | PM111 | Vacuubrand MD1 Vacuubrand catalog | N |