FELIX instructions for Petals

From Atlas Wiki
Revision as of 12:01, 21 May 2024 by Aalonso@nikhef.nl (talk | contribs) (add more info and trim scan)
Jump to navigation Jump to search

Back to DAQ systems

R5 petal setup at Nikhef May 2024

How to configure a petal (main instructions taken from DESY repo https://gitlab.cern.ch/desy-atlas/itk/petal-testing):

cd into the petal-testing directory and then execute the following commands:

  • Setup the FELIX dependencies: source dependencies/setupFELIX.sh
  • Initialize the FLX card: flx-init

It's normal if it says that all the channels are not aligned even if at least one actually is, we don't know why, but SR1 with staves sees the same.

  • Invert the polarity (for lpGBTv1): flx-config set GBT_RXPOLARITY=0xFFFFFFFF
  • Verify the status of the PODs: flx-info POD
  • Check that all connected links are aligned: flx-info GBT

If testing the PPB R5 Vancouver Petal:

  • Configure the elinks on your FELIX card: source configs/elinks/elinks_petal_R5_640Mbs.sh
  • Check your config: elinkconfig

Click on Read Cfg, then you can Quit.

  • Push the lpGBT config to the petal chipset : fice -G0 -I71 configs/lpgbt/lpgbt_PT_M_LH_V1_Pri_hex.cnf

If this command takes a long time, it's because of the LV PSU, probably due to have been providing power for a long time.

  • Verify this has worked (you should see the line "Compared 336 values, found 0 differences"): fice -G0 -I71 -C configs/lpgbt/lpgbt_PT_M_LH_V1_Pri_hex.cnf
  • Start FELIXCore and don't close this terminal: startFelixcore


In a second remote terminal session cd into the petal-testing directory and then execute the following commands:

  • Configure the YARR dependencies: source dependencies/setupYARR.sh
  • Activate the AMAC: write_amac_ppb 9 1 0 0

This will increase the current in the LV PSU, typically from 165 mA to 405 mA, at least these are the numbers at Nikhef with the R5 Vancouver petal. It's important to check this changes in the consumption, since it confirms there's communication with the chips.

In the terminal running Felixcore, a new line will appear saying "Opening DEVICE 0 for the To-FLX thread".

  • Confirm there's communication with the HCCs via a register dump scan: python3 scantools/run_YARR.py -c scanSetup_regDump.json --infile-dir scantools/configs_PPB_Vancouver_R5 execute it twice!! (once per HCC)

After the 2nd time, there shouldn't be lines like "There were no results for chip Stave_PPB_hcc1".

Also: after the first regsiter dump scan, the current in the LV PSU will increase from 405 mA to 514 mA, and Felixcore will show the lines "Subscription from endpoint 127.0.0.1:37645 for elink 0" and "Subscription from endpoint 127.0.0.1:39225 for elink 2". After the second regsiter dump scan the current will increase from 514 mA to 605 mA, and Felixcore will show the lines "Subscription from endpoint 127.0.0.1:42045 for elink 0" and "Subscription from endpoint 127.0.0.1:46479 for elink 2".


Performing a Trim Scan

The trimScanWithRange optimizes the trim and threshold values of the chip at the same time, thus this scan takes a while. Execute it via python3 scantools/run_YARR.py -c scanSetup_trim.json --infile-dir scantools/configs_PPB_Vancouver_R5. In the data directory, you should now find a subdirectory called XXXXXX_std_trimScanWithRange.