Sensor connections
Feedthroughs
This page contains the information about the connections made with the sensors trough the electrical feedthroughs. There are three feedthroughs as seen on the image below, the different feedthroughs will be numbered. We will also, when possible try to keep every feedthrough dedicated to one sort of sensor. The pins will be number 1 to 9 from top-left to bottom right as showed in the schematic below.
|
Temperature sensor
Temperature sensor 1
The first temperature sensor will be connected using a D-sub feedthrough number 2. And will be connected using pin 1 (blue) and pin 6 (red). To be able to read-out the sensor a voltage of 3.3V is applied over the sensor and a 1K resistor. The voltage over the sensor is measured and conversed into a resistance, which will be used for determining the temperature.
Temperature sensor 2
tekst
Temperature sensor 3
tekst
Silicon Photomultipliers
SiPM 1
The first SiPM will be connected using a D-sub feedthrough number 3. And will be connected using pin 1 (grey) and pin 6 (white).
Impedance on cables
Every cable has a certain impedance