(Update for 2024) |
|||
| Line 73: | Line 73: | ||
| | | | ||
|- | |- | ||
| − | |Test if signal from S13360-6050-PE is good with current VULCAN read-out board - if not, work with ET to design new circuit | + | |Test if signal from S13360-6050-PE is good with current VULCAN read-out board - if not, work with ET to design new circuit - also use Hamamatsu board and compare |
|Anna/Joost | |Anna/Joost | ||
| | | | ||
| | | | ||
|- | |- | ||
| − | |Test how signal from S13360-6050PE degrades when connected over a long cable as will be the case in XAMS - decide if we need pre-amplifier inside XAMS | + | |Test how signal from S13360-6050PE degrades when connected over a long cable as will be the case in XAMS - decide if we need pre-amplifier inside XAMS - together with ET |
| − | | | + | |Noor/Joost |
| | | | ||
| | | | ||
|- | |- | ||
| − | |Procure SiPM read-out board - 4 channels, S13360-6050PE/CS SiPMs - from ET | + | |Procure SiPM read-out board - 4+ channels, S13360-6050PE/CS SiPMs - from ET, possibly a total of 4 or so if economic |
|Anna/Joost | |Anna/Joost | ||
|Previous SiPM test results | |Previous SiPM test results | ||
| Line 89: | Line 89: | ||
|- | |- | ||
|Install and test 16-channel digitiser for XAMS | |Install and test 16-channel digitiser for XAMS | ||
| − | |AP | + | |AP/Marieke |
| − | | | + | |XAMS test run finished? |
| | | | ||
|- | |- | ||
| Line 98: | Line 98: | ||
| | | | ||
|- | |- | ||
| − | |Re-design the guts of XAMS to include SiPM readout of a possible fluorescence signal (new PTFE sleeve) | + | |Measure rest-gas composition in XAMS |
| − | |Joost | + | |Noor |
| + | | | ||
| + | | | ||
| + | |- | ||
| + | |Measure outgassing from PTFE | ||
| + | |Noor | ||
| + | | | ||
| + | | | ||
| + | |- | ||
| + | |Re-design the guts of XAMS to include SiPM readout of a possible fluorescence signal (new PTFE sleeve). Ask advice from Marieke and from Oscar (from MT). Come up with a proposal. | ||
| + | |Joost/Noor | ||
| | | | ||
| | | | ||
| Line 124: | Line 134: | ||
| | | | ||
|- | |- | ||
| + | |Analyse data from XAMS. Ask Carlo for help | ||
| | | | ||
| + | | | ||
| + | | | ||
| + | |- | ||
| + | |Analyse data from VULCAN. Ask Marjolein for help | ||
| | | | ||
| | | | ||
Revision as of 09:28, 11 September 2024
Update September 2024 - joint XAMS project
| Projects | DRI | Main dependencies | Status | Finish by |
|---|---|---|---|---|
| Finalise reflectivity measurements of DUNE cryostat components | Marjolein/Vikas/Corryenne | Oct 2024 | ||
| Fluorescence measurements in VULCAN | Anna | |||
| Delayed electrons and g1 in XAMS | Joost | |||
| Calibration of XAMS | Noor | |||
| Reflectance of DUNE cryostat components | Corryenne | June 2024 | ||
| Measure time stability of D2 lamp intensity | ||||
| Determine effect of exposure to radiation on fluorescence of plastics |
| Task - hardware | DRI | Dependencies | Status |
|---|---|---|---|
| Design SiPM holder for fluorescence measurements | Anna | Reflectivity study finished | |
| Set up and test cooling system for samples, SiPM | Anna | ||
| Fully reconfigure VULCAN for fluorescence measurements | Anna | cooling system and SiPM holder ready | |
| Test if signal from S13360-6050-PE is good with current VULCAN read-out board - if not, work with ET to design new circuit - also use Hamamatsu board and compare | Anna/Joost | ||
| Test how signal from S13360-6050PE degrades when connected over a long cable as will be the case in XAMS - decide if we need pre-amplifier inside XAMS - together with ET | Noor/Joost | ||
| Procure SiPM read-out board - 4+ channels, S13360-6050PE/CS SiPMs - from ET, possibly a total of 4 or so if economic | Anna/Joost | Previous SiPM test results | |
| Install and test 16-channel digitiser for XAMS | AP/Marieke | XAMS test run finished? | |
| Set up XAMS to start a run | Tobias | ||
| Measure rest-gas composition in XAMS | Noor | ||
| Measure outgassing from PTFE | Noor | ||
| Re-design the guts of XAMS to include SiPM readout of a possible fluorescence signal (new PTFE sleeve). Ask advice from Marieke and from Oscar (from MT). Come up with a proposal. | Joost/Noor |
| Task - software/analysis | DRI | Dependencies | Status |
|---|---|---|---|
| XAMS MC - simulate calibration sources, g1 expectation | AP/? | ||
| VULCAN MC - simulate photon paths/coverage fraction of SiPMs | Anna | ||
| Based on XENON1T/nT data, calculate possible PTFE fluorescence efficiencies and compare to sensitivity achievable in VULCAN | Pranati | ||
| Analyse data from XAMS. Ask Carlo for help | |||
| Analyse data from VULCAN. Ask Marjolein for help |
Vacations, Meetings, and general availability of people
General:
Tina:
AP:
- Working from home in Sept.
Marjolein:
Vikas:
Pranati:
Anna (MSc, Sept 2024 - July 2025):
Joost (MSc, Sept 2024 - July 2025):
- Lectures on Monday 9-11
Noor (BSc internship, Sept 2024 - Jan 2025):