==Cleaning and stress tests done to solder flux samples==
 
==Cleaning and stress tests done to solder flux samples==
 +
 +
=== Cleaning ===
 +
 +
Each sample was wiped for 30 seconds with the corresponding cleaning agent. In the case Tickopur an ultrasonic bath was used at 30°C temperature for 10 min each step and a rinse in DI water.
  
 
[[File:Cleaning summary summary.png|thumb|left|Sample numbers corresponding to the flux type and cleaning done|652x652px]]
 
[[File:Cleaning summary summary.png|thumb|left|Sample numbers corresponding to the flux type and cleaning done|652x652px]]
 +
 +
 +
=== Results of Cleaning ===
 +
 +
Value corresponds to the ratio of amount of light left after the cleaning with respect to the amount of light present before the cleaning.