- <s>Test SiPM signal (noise) when pump and lamp are on, fix if necessary</s> | - <s>Test SiPM signal (noise) when pump and lamp are on, fix if necessary</s> | ||
| − | - Connect and test the Zurich board - signal-to-noise | + | - <s>Connect and test the Zurich board - signal-to-noise</s> |
- <s>Figure out what changes if any are needed to bias and read the fluorescence measurement SiPMs</s> | - <s>Figure out what changes if any are needed to bias and read the fluorescence measurement SiPMs</s> | ||
| Line 126: | Line 126: | ||
|Preliminary analysis of sensitivity needs finished | |Preliminary analysis of sensitivity needs finished | ||
| | | | ||
| − | | | + | |Nov |
|- | |- | ||
|Design SiPM array holder for reflectance/transmission | |Design SiPM array holder for reflectance/transmission | ||
| Line 174: | Line 174: | ||
|Emily (Jasmijn) | |Emily (Jasmijn) | ||
| | | | ||
| − | |Oct | + | |Oct 28 |
|- | |- | ||
|Review past reflectivity setup design/sample holder (that had XENON in mind) in light of DUNE needs | |Review past reflectivity setup design/sample holder (that had XENON in mind) in light of DUNE needs | ||
Revision as of 08:07, 19 October 2022
Update September 2022
| Task (measurements) | DRI | Main dependencies | Status | Finish by |
|---|---|---|---|---|
| Measure fluorescence efficiency of PTFE | Emily | |||
| Measure reflectance of cryostat components | Marjolein | |||
| Measure optical properties of Arapuca components | Vikas | |||
| Measure the spectrum of the D2 lamp | Jasmijn | Dec 1 | ||
| Gain characterization of SiPMs | Jasmijn | |||
| Measure excitation beam intensity as function of SiPM position and slit width | ||||
| Measure time stability of D2 lamp intensity | ||||
| DN vs temperature characterization of SiPMs | ||||
| Determine effect of exposure to radiation on fluorescence of plastics |
| Task (hardware) | DRI | Main dependencies | Status | Finish by |
|---|---|---|---|---|
| Marjolein | Vikas | Done | Sept 23 | |
| Emily | Done | Sept 23 | ||
| Emily | Done | Sept 27 | ||
| Emily | Done | Oct 1 | ||
- - - - |
Marjolein (Jasmijn) | Pressure read-out working | Done | Oct 1 |
| SiPM signal output
- - - - - |
Emily | Vacuum/light leak eliminated | Oct 7 (Oct 20 for the new board) | |
| Design SiPM array holder for fluorescence | Emily | Preliminary analysis of sensitivity needs finished | Nov | |
| Design SiPM array holder for reflectance/transmission | Marjolein | Analysis of physics goals finished | Nov | |
| Marjolein (Jasmijn) | Nov | |||
| Calibrations start | Emily Marjolein | Minimum working setup | End Nov | |
| Get sample holder (fluorescence design) built | Emily | Nov | ||
| Set up slow-control read-out and data storage, monochromator motor control | Vikas -> ? | Dec | ||
| Install cooling system (LN2 plate, thermal shorts, LN2 fill system, super insulation) | Emily | Dec |
| Task (review and calculations) | DRI | Status | Finish by |
|---|---|---|---|
| Estimate sensitivity needs of the PTFE fluorescence measurement (preliminary, rough calculation) | Emily (Jasmijn) | Oct 28 | |
| Review past reflectivity setup design/sample holder (that had XENON in mind) in light of DUNE needs | Marjolein | Oct 30 | |
Update August 2022
PhDs:
Vikas: At CERN until end of the year. Will work a little bit with CT technician to get code and slow control in good shape.
Emily: Focus on getting the SiPM signals to the digitisers. Work with Hans from ET department.
Marjolein: Focus on getting the data from the digitisers into a good format. Work with Maricke/Joran to copy XAMS read-out software.
Undergraduates:
Ilze (start Sept 12, HBO internship): Get vacuum chamber working correctly, design improved SiPM holder. Measure beam intensity as function of distance using SiPM
Jasmijn (start Sept, AUC capstone project): Estimate fluorescence efficiency of PTFE based on Xenon lone-S2 rates. Measure lamp spectrum.
Not free: Monday 11-14, Tuesday 11-13, Wednesday 9-12, Thursday 16-18, Friday 16-18
Lucia (January 2023): Measure the SiPM DC rate as a function of temperature
Projects for distibution
- SiPM array and holder --> reflectivity design (modelling/ mechanical viability/ feedthrough positioning)
- SiPM array and holder --> fluorescence design (modelling/ mechanical viability/ movement inside chamber/ solid angle coverage)
- Cooling system for sample holder/SiPMs (CAD/COMSOL/ LN2 bath)
- Put together a plan for data taking