Upgrade/RadiationTestBirmingham

From LHCb Wiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Three types of samples:

  * number of samples: three (different types of glue: StycastFT2850, EP37-3FLFAO, Polytec TC423)
  * assembly: titanium (1.8mm), adhesive, 0.2mm), silicon (0.5 mm)
  * size: 50mm x 17mm x 2.5mm
  * desired irradiated surface: 42mm x 17mm
  * desired irradiation load: 2x10^15 1-MeV-neutron equivalent / cm^2
  * number of samples: three (different types of glue: StycastFT2850, EP37-3FLFAO, Polytec TC423)
  * assembly: aluminium (2mm), adhesive (10mm), aluminium (2mm)
  * size: 10mm x 14mm x 2mm
  * desired irradiated surface: over entire adhesive (~10mm x 10mm)
  * desired irradiation load: 2x10^15 1-MeV-neutron equivalent / cm^2
  * number of samples: three (different types of coating: Torlon, Polyurethane, XXX)
  * assembly: aluminium plate (1mm) covered with very thin layer of coating
  * size: minimally 3x3cm (size can be increased, if that makes it easier to handle samples)
  * desired irradiated surface: single 'spot' profile is sufficient
  * desired irradiation load: 1x10^16 1-MeV-neutron equivalent / cm^2