Upgrade/RadiationTestBirmingham

From LHCb Wiki
Revision as of 09:12, 8 September 2017 by Wouterh@nikhef.nl (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Three types of samples:

  * number of samples: three (different types of glue: StycastFT2850, EP37-3FLFAO, Polytec TC423)
  * assembly: titanium (1.8mm), adhesive, 0.2mm), silicon (0.5 mm)
  * size: 50mm x 17mm x 2.5mm
  * desired irradiated surface: 42mm x 17mm
  * desired irradiation load: 2x10^15 1-MeV-neutron equivalent / cm^2
  * number of samples: three (different types of glue: StycastFT2850, EP37-3FLFAO, Polytec TC423)
  * assembly: aluminium (2mm), adhesive (10mm), aluminium (2mm)
  * size: 10mm x 14mm x 2mm
  * desired irradiated surface: over entire adhesive (~10mm x 10mm)
  * desired irradiation load: 2x10^15 1-MeV-neutron equivalent / cm^2
  * number of samples: three (different types of coating: Torlon, Polyurethane, XXX)
  * assembly: aluminium plate (1mm) covered with very thin layer of coating
  * size: minimally 3x3cm (size can be increased, if that makes it easier to handle samples)
  * desired irradiated surface: single 'spot' profile is sufficient
  * desired irradiation load: 1x10^16 1-MeV-neutron equivalent / cm^2