Upgrade/RadiationTestBirmingham
Revision as of 10:05, 13 June 2017 by Wouterh@nikhef.nl (talk | contribs)
Three types of samples:
- A: glue mechanics tests (see picture,
packaged for shipping) * number of samples: three (different types of glue: StycastFT2850, EP37-3FLFAO, Polytec TC423) * assembly: titanium (1.8mm), adhesive, 0.2mm), silicon (0.5 mm) * size: 50mm x 17mm x 2.5mm * desired irradiated surface: 42mm x 17mm * desired irradiation load: 2x10^15 1-MeV-neutron equivalent / cm^2
- B: glue heat conductivity tests (see picture,
ready for shipping) * number of samples: three (different types of glue: StycastFT2850, EP37-3FLFAO, Polytec TC423) * assembly: aluminium (2mm), adhesive (10mm), aluminium (2mm) * size: 10mm x 14mm x 2mm * desired irradiated surface: over entire adhesive (~10mm x 10mm) * desired irradiation load: 2x10^15 1-MeV-neutron equivalent / cm^2
- C: RF box coating tests (see picture ready for shipping)
* number of samples: three (different types of coating: Torlon, Polyurethane, XXX) * assembly: aluminium plate (1mm) covered with very thin layer of coating * size: minimally 1x1cm (size can be increased, if that makes it easier to handle samples) * desired irradiated surface: single 'spot' profile is sufficient * desired irradiation load: 1x10^16 1-MeV-neutron equivalent / cm^2