Difference between revisions of "Upgrade/RadiationTestBirmingham"

From LHCb Wiki
Jump to navigation Jump to search
Line 8: Line 8:
 
   * desired irradiation load: 2x10^15 1-MeV-neutron equivalent / cm^2
 
   * desired irradiation load: 2x10^15 1-MeV-neutron equivalent / cm^2
  
*  B: glue heat conductivity tests (see picture)
+
*  B: glue heat conductivity tests ([https://surfdrive.surf.nl/files/index.php/s/0B26ZlYFqSSzMKB see picture])
 
   * number of samples: three (different types of glue: StycastFT2850, EP37-3FLFAO, Polytec TC423)
 
   * number of samples: three (different types of glue: StycastFT2850, EP37-3FLFAO, Polytec TC423)
 
   * assembly: aluminium (2mm), adhesive (10mm), aluminium (2mm)
 
   * assembly: aluminium (2mm), adhesive (10mm), aluminium (2mm)

Revision as of 12:16, 7 June 2017

Three types of samples:

  * number of samples: three (different types of glue: StycastFT2850, EP37-3FLFAO, Polytec TC423)
  * assembly: titanium (1.8mm), adhesive, 0.2mm), silicon (0.5 mm)
  * size: 50mm x 17mm x 2.5mm
  * desired irradiated surface: 42mm x 17mm
  * desired irradiation load: 2x10^15 1-MeV-neutron equivalent / cm^2
  * number of samples: three (different types of glue: StycastFT2850, EP37-3FLFAO, Polytec TC423)
  * assembly: aluminium (2mm), adhesive (10mm), aluminium (2mm)
  * size: 10mm x 14mm x 2mm
  * desired irradiated surface: over entire adhesive (~10mm x 10mm)
  * desired irradiation load: 2x10^15 1-MeV-neutron equivalent / cm^2
  • C: RF box coating tests (see picture)
  * number of samples: three (different types of coating: Torlon, Polyurethane, XXX)
  * assembly: aluminium (1mm) on both sides covered with very thin layer of coating
  * size: minimally 1x1cm (size can b increased, if that makes it easier to handle samples)
  * desired irradiated surface: single 'spot' profile is sufficient
  * desired irradiation load: 1x10^16 1-MeV-neutron equivalent / cm^2