W0039_G11 50 um n-in-p
Depletion at -20 V
Breakdown at -120 V
Threshold at 700 e
Equalisations at -20, -40, -60, and -100 Volts

10. Small angle scan
Bias Voltage: -100 V
Threshold: 1000e
One spill per angle
Angles -21, -13 -8, -5, -3, -2, -1, 0, 1, 2, 3, 5, 8, 13, and 21

15. Threshold scan for timing resolution
20 spills per step (~5 minutes per step)
Bias voltage: -100 V
Angles: 0 and 89 degrees. (perpendicular to get all charge in a single pixel and grazing to probe drift distance)
Thresholds: 1000, 900, 800, 700, and lower if possible: 650, 600, 550, 500

20. Bias scan for timing resolution
20 spills per step (~5 minutes per step)
Angles: 0 and 89 degrees. (perpendicular to get all charge in a single pixel and grazing to probe drift distance)
Bias voltages: 5, 10, 15, 20, 30, 40, 50, 60, 70, 80, 90, and 100 V

25. Threshold scan for spatial resolution
10 spills per step (~2.5 minutes)
Bias voltage: 25 V (?)
Angle: 45 degrees
Thresholds: 1000, 900, 800, 700, and lower if possible: 650, 600, 550, 500

30. Angle scan for spatial resolution
10 spills per step (~2.5 minutes)
Bias voltage: 25 V (?)
Angles: 20, 25, 30, 35, 38, 40, 42, 44, 46, 48, 50, 52, 55, 60, and 65 degrees

40. Check for timing uniformity of DUT pixel matrix
For 20, 60, 100V bias?
lowest thl possible (700?)
20 spills per position (~5 minutes per step)
Depending on beam spot size, scan complete DUT (e.g. 1 around each corner and 1 in middle for big spot size)

50. Grazing angle

60. Tp calibration (sunday)

Edit | Attach | Print version | History: r9 < r8 < r7 < r6 < r5 | Backlinks | Raw View | Raw edit | More topic actions...
Topic revision: r6 - 2018-10-13 - RobbertGeertsema
 
This site is powered by the TWiki collaboration platform Powered by Perl This site is powered by the TWiki collaboration platformCopyright © 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.