W0020_J07 200 um n-in-p
Depletion at ?? V
Breakdown at |Vbias| > 300 V
Threshold at 700 e
Equalisation at -300 Volts
10. Small angle scan
Bias Voltage: -300 V, DUT X 47 mm
Threshold: 700e
One spill per angle
Angles -8, -5, -3, -2, -1, 0, 1, 2, 3, 5, 8
20. Bias scan for timing resolution
### DUT X 47 mm ###
Telescope: 200 V
10 spills per step
Angle: 0 degrees
Bias voltages (negative!): 25, 50, 75, 100, 125, 150, 175, 200, 225, 250, 275, 300
21. Angle scan at grazing angles
### DUT X 40 mm ###
Bias: -300 V, Telescope: 200 V
5 spills per step
Real angles: 86, 87.5, 88.4, 88.8, 91.2
22. Bias scan at grazing angle
### DUT X 40 mm ###
Telescope: 200 V
10 spills per step (~5 minutes per step)
Angle: 88.8 degrees.
Bias voltages (negative): 50, 100, 150, 200, 250, 300
23. 2D Scan: angle and bias
Telescope: 200 V
5 spills per step
Threshold: 700 e
Angles: 0 to 80 (inclusive) in steps of 5 degrees.
Bias voltages (negative): 300, 200, and 100V
Angle [degrees], DUT X [mm]
0 47
5 46
10 46
15 45
20 45
25 44
30 44
35 43
40 43
45 42
50 42
55 42
60 41
65 41
70 41
75 41
80 41
50. Threshold scan - OPTIONAL
### DUT X 47 mm ###
5 spills per step
Bias voltage: -300 V, Telescope: 200 V
Angle: 0 degrees
Thresholds: 1600, 1400, 1200, 1000, 900, 800, 700, and lower if possible: 600
55. Threshold scan at grazing anle - OPTIONAL
### DUT X 40 mm ###
5 spills per step
Bias voltage: -300 V, Telescope: 200V
Angle: 88.8 degrees
Thresholds: 1600, 1400, 1200, 1000, 900, 800, 700, and lower if possible: 600