Difference between revisions of "Daily update"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
− | + | ===17 February 2017=== | |
* <p>straight knife measured to be bent with deviations up to 20 microns</p> | * <p>straight knife measured to be bent with deviations up to 20 microns</p> | ||
* <p>cutting wheel quite possibly damaged</p> | * <p>cutting wheel quite possibly damaged</p> | ||
Line 5: | Line 5: | ||
* <p>movement in 10s of microns while cutting observed (could be solved with new/better knife and wheel)</p> | * <p>movement in 10s of microns while cutting observed (could be solved with new/better knife and wheel)</p> | ||
− | ''ToDo:'' | + | ==''ToDo:''== |
1) repair knife and wheel | 1) repair knife and wheel | ||
2) measure friction due to vacuum | 2) measure friction due to vacuum | ||
3) check movement with deeper wheel bite and/or smaller cut angle | 3) check movement with deeper wheel bite and/or smaller cut angle |
Revision as of 08:50, 20 February 2017
17 February 2017
straight knife measured to be bent with deviations up to 20 microns
cutting wheel quite possibly damaged
attempted cutting of module with silicon removed showed that the module is not immobile during cutting
movement in 10s of microns while cutting observed (could be solved with new/better knife and wheel)
ToDo:
1) repair knife and wheel 2) measure friction due to vacuum 3) check movement with deeper wheel bite and/or smaller cut angle